Hilti Ul U465, Framing Members* - Steel Studs - In lieu of It

Hilti Ul U465, Framing Members* - Steel Studs - In lieu of Item 2 - Channel shaped studs, min depth as indicated under Item 5, spaced a max of 24 in. Users of fire resistance assemblies are advised to consult the general Guide Information for each product category and each group of assemblies. Hourly rating ProSTUD minimum thickness ProSTUD UL design no. The UL listings on this page may be modified with this method and maintain the two hour rating. The Guide Information includes specifics concerning alternate materials and alternate methods of construction. C. OC. As applied to elements of buildings, the fire-resistance rating classifies the ability of an assembly to confine and isolate fire within a zone comprised of fire resistance-rated walls, ceiling and floor assemblies. Only products which bear UL's Mark are considered as Classified, Listed, or Recognized. Batts and Blankets, Item 3D, and Adhesive, Item 11, are required. BATTS AND BLANKETS* - 5/8” THICK, 4’ WIDE, ATTACHED TO STEEL STUDS AND FLOOR AND CEILING TRACK WITH 1” LONG, TYPE S SELF-TAPPING STEEL SCREWS SPACED 8” O. (Preferences may be based on material costs, ease of construction, preference of trusted builders, or material performance over time. Click here to discover more. to validate the fire rating of any fire-resistant system, HILTI primarily uses UL to conduct the testing and issue certification accordingly. 1/2" Interior gypsum wallboard 2"x4" Wood studs 24” O. WHEN ATTACHED TO ITEM 6 (FURRING CHANNELS), WALLBOARD IS SCREW ATTACHED TO FURRING CHANNELS Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively. If you have a one hour wall constructed to a UL listing, say U465. Discover Hilti high-performance tools, fasteners, and digital solutions built to improve safety, accuracy, and efficiency on every jobsite. Veiw our resources on Viper-X UL Assemblies here! National Gypsum® is a leading supplier of gypsum board and drywall products. UL ONLINE CERTIFICATIONS DIRECTORY BXUV. Explore STI's innovative solutions for firestopping and pathway systems in various industries. Only products which bear UL's Mark are considered Certified. This library contains a list of each Head of Wall assembly that pertains to each of these TSN product lines, followed by a linked Table of Contents for easy access to each of the various details. From healthcare to data communications, find cost-effective and sustainable solutions for your projects. UL systems classification deems valid across all the countries following UL/ASTM standard and holds high credibility. ALONG EDGES OF BOARD AND 12: O. They may be used as a reference by architects, engineers, other design professionals, contractors, building code officials, or other competent construction industry trade personnel considering the selection, specification and use of National Gypsum Users of fire resistance assemblies are advised to consult the general Guide Information for each product category and each group of assemblies. ProSTUD Chase or Double Stud—Fire Assemblies A UL design no. Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements covering the installation and use of UL Certified products, equipment, system, devices, and materials. I used Hilti UL assembly W-L-1054 to seal all my walls. ) CEMSCO products are manufactured to the standards established by the American Iron and Steel Institute. Fire Resistance DensGlass Sheathing is noncombustible as described and tested in accordance with ASTM E136 or CAN/ULC S114. Can you add materials on the outside of the wall? Would one be able, say, to apply plywood with screws to the rated assembly? BXUV - Fire Resistance Ratings - ANSI/UL 263 Certified for United States BXUV7 - Fire Resistance Ratings - CAN/ULC-S101 Certified for Canada See General Information for Fire-resistance Ratings - ANSI/UL 263 Certified for United States Design Criteria and Allowable Variances UL Solutions is a global expert in Certification, Testing, Inspections, auditing etc. My inspector says for data stubs my assembly doesn't work because the 1054 specifically requires strapping on both sides of the wall. The ratings relate Over 30 years of experience in providing internationally approved and tested firestop systems, premium software and support to save lives and buildings from fire UL U423, U425 Exterior Walls, Steel Stud (Load-Bearing), with fiberglass batt insulation These gypsum wallboard system details are intended solely as technical support incident to the sale and use of National Gypsum Company products. BXUV - Fire Resistance Ratings - ANSI/UL 263 Certified for United States BXUV7 - Fire Resistance Ratings - CAN/ULC-S101 Certified for Canada See General Information for Fire-resistance Ratings - ANSI/UL 263 Certified for United States Design Criteria and Allowable Variances Five of The Steel Network’s product lines are approved for use in UL® Classified Head of Wall Assemblies: VertiClip® SLD and DSLD; and VertiTrack® VTD, VTX, and VT.